The Gemco Series 2110 Shut Height Monitor gives you a highly accurate readout of shut height as you jog the shut height motor or manually adjust the shut height mechanism of your press.
Once proper shut height is determined, the readout can be recorded for use the next time the die is used in the same press, significantly reducing setup time and the number of test parts.
Convenience and Efficiency, Series 2110 Shut Height Monitor System Quickens the Setup Time Pace:
FEATURES
When ordering, you must make a selection from each of the following options: Input, Limit Output, Digital Output, Enclosure and Two Channel Analog Output.
NOTE: This is a customized product and is not returnable. Please contact us if you have any questions regarding the suitability of this product to your application. Lead time is 3-6 Weeks after receipt of order.
Shut Height Monitor | |
Power Requirements | 85 - 265 VAC 50/60 Hz; Internally Fused at 1.5 Amps |
Temperature | Operating: 32° to 131° F; Storage: 0° to 150° F |
Environmental | Humidity: 5% to 95%; Non-condensing |
Shock & Vibration | Tested to: MIL-STD 810E, Method 514.4, Category 10, 20 - 2K Hz, 2G sine, 0.04 G2/Hz random. To UL 491, SA 19, 10 - 150 Hz, 10G sine. |
Electromagnetic Compatibility | Compatibility — Tested to: IEC 801-2, Level 5 (Electrostatic discharge requirements); IEC 801-4, Level 4 (Electrical fast transient/burst requirements);IEC 801-5, Level 3,5 (Surge immunity requirements) |
Memory Retention Time | Maintains last programmed values for ten (10) years without power. |
Relay Contact Ratings | All relays rated UL & CSA for 1⁄4 HP, 125 to 250 VAC; 8A 250 VAC, 30 VDC, Shock Resistant to 10 G |
Movement Input | 85 - 265 VAC, 12 mA (rms) maximum; optical isolated to 3200 VDC/2250 VAC |
Program Mode Key Input | Dry Contact; Open Collector (drain) ONLY; +5 VDC maximum — Current 0.2 mA |
RS - 232 Output | 115.2 K baud |
RS - 485 Output | 115.2 K baud |